Severe mechanical hemolysis after transcatheter closure of a traumatic ventricular septal defect using the amplatzer atrial septal occluder
Tang Liang Tang Jian-Jun Fang Zhen-Fei Hu Xin-qun Shen Xiang-Qian Zhou Sheng-hua · 2016
收藏
阅读量:79
期刊名称:
International Heart Journal   2016 年 57 卷 4 期
发表日期:
2016
摘要:
Traumatic ventricular septal defect (VSD) resulting from chest trauma, either penetrating or blunt, is a relatively rare occurrence. Herein, we describe the case of a previously healthy 26-year-old man who presented with congestive heart failure, which was secondary to a large traumatic VSD following violent blunt chest trauma. The traumatic VSD was initially closed percutaneously using an Amplatzer atrial septal defect occluder. Post-device closure, however, the patient developed severe intravascular hemolysis refractory to medical treatment. The patient subsequently underwent surgical removal of the Amplatzer device, with concomitant VSD patch closure.